Charging power is a setting, not a command: write max_charge_rate once and the charger keeps it across sessions until you change it. See Settings for how settings differ from commands.

1. Check the device supports it

If settings.max_charge_rate is missing, the charger doesn’t expose a power cap in kW. Stay inside its min and max, on a multiple of step.

2. Write the setting

Send only the settings you want to change.
Settings return 200, not 202, and don’t create an action. A value outside the bounds or off the step grid returns 422 SETTING_OUT_OF_RANGE. max_charge_rate and max_charge_current are the same cap in two units: send one, or you get 422 UNSUPPORTED_SETTING_COMBINATION.

3. Confirm

Read the device again: settings.max_charge_rate.value shows 7.4. See Pull for how fresh a read is. To cap a single session instead, send power or current on the charge command. See Start and stop a session.

Cap for a grid event, then restore

A grid operator may require a lower limit for a few hours, such as 4.2 kW. Amps keeps no record of the previous value, so save settings.max_charge_rate.value before you write the cap, and write it back when the event ends.
The cap also applies to sessions that start during the event. Some cars only slow down after a pause in the session, so if the limit is a hard obligation, push idle for the event instead. The restore overwrites any change someone else made meanwhile: read the device first if that matters.

Next steps

Start and stop a session

Charge now, pause, or charge inside a time window.

Settings

Every setting code and how writes work.